576
Precision Infrared Thermometer
Users Manual
March 2005
© 2005 Fluke Corporation. All rights reserved.
All product names are trademarks of their respective companies.
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
Seitenansicht 0
1 2 3 4 5 6 ... 32 33

Inhaltsverzeichnis

Seite 1 - Users Manual

576Precision Infrared Thermometer Users ManualMarch 2005© 2005 Fluke Corporation. All rights reserved.All product names are trademarks of their respe

Seite 2 - LIABILITY

576Using the CameraIn addition to the thermometer functionality the Model 576 comes with a digital built-in camera to documentate the measured places.

Seite 3 - Safety Information

11576signals: “Flash has charged”. The flash willnow fire automatically.7. For the next measurement, repeat points 5 and 6.8. Once you have taken all

Seite 4 - Table of Contents

12576Make sure that the target is larger than the unit’s spot size. The smaller the target, the closer you should be to it.Field of View

Seite 5 - Introduction

13576STANDARD MODELOptical Chart30001201.00024SPOT DIA. (IN)SPOT DIA. (mm)DISTANCE: SENSOR TO OBJECT (mm)DISTANCE: SENSOR TO OBJECT (IN)FOCUS POINT D:

Seite 6

14576Emissivity - ExplanationReflected energyEmitted energyTransmitted energyEMISSIVITYTargetThe amount of infraredenergy radiated by anobject depends

Seite 7

576EmissivityTochoose the emissivity of a mate-ial, press EMISS.The display shows a materialname, an emissivity value, and thecalculated temperature v

Seite 8 - Delivery Content

16576Emissivity - Unknown ValueToadjust the unit’s emissivity value for a material with unknown emissivity, plug in theprobe.Pull the unit’s trigger.

Seite 9 - Batteries and Measurement

17576Emissivity Table (Selected Values)Aluminum* 0.30Asbesto 0.95Asphalt 0.95Basalt 0.70Brass* 0.50Brick 0.90Carbon 0.85Ceramic 0.95Concrete 0.95Coppe

Seite 10 - Using the Camera

18576IMPORTANT! Before you install the software you must connect the unit with the PC to confi gure the USB interface.Proceed as follows:Connect the u

Seite 11

19576For the software installation follow the information on the screen.Start the software with a double-click on the IRGraph icon on the desktop.The

Seite 12 - Field of View

2576LIMITED WARRANTY AND LIMITATION OF LIABILITYThis Fluke product will be free from defects in material and workmanship for one year from the date of

Seite 13 - Optical Chart

576DisplayThe last ten measurements areshown in the bar graph on theunit’s display. Auto Range of thebar graph is automatically definedbythe measured

Seite 14 - Emissivity - Explanation

21576DataPress Data once to activate the logmode of the thermometer and thecamera. With the appropriate log-ger file configuration, you can storetempe

Seite 15 - Emissivity

22576SetupHigh alarm (HiAl) generates an audible and visual(flashing LED and laser) alarm ifthe temperature is above the setpoint.Low alarm (LoAl) gen

Seite 16 - Emissivity - Unknown Value

23576This function is used with a selectedemissivity to add or subtract an offsetlue (±10°C/±18°F) to the temperatureThe OFFSET feature allows thetemp

Seite 17

24576Mode Toactivate the MAX mode, pressMODE until the MAX symbolappears . The measured maximumtemperature is displayed as longas the trigger is pulle

Seite 18 - Hardware and Software Setup

25576...MIN, DIF, AVG,Toactivate the MIN mode, pressMODE until the MIN symbolappears. The measured minimumtemperature is displayed as longas the trigg

Seite 19

26576Mode - Thermocouple SettingsLockC/FAuto/AllLaserflashLtd. AccessSet DefaultBacklightBuzzerTC-J/TC-KNTC/TCTime/DatePhotoflashONOpen the battery

Seite 20

27576DIP SwitchesSome functions of the unit be changed by usingthe DIP switches. These switches are located inthe Battery compartement of the unit.Loc

Seite 21

28576TroubleshootingSymptomDisplay Code Problem ActionCamera cannot Driver installation Open send photos failed Harware Manager on to the PC the P

Seite 22

29576SymptomDisplay Code Problem ActionPhoto quality Light is insufficient for photo Use Photoflash diminished with without flash always on (Dip sw

Seite 23 - Clear Images

3576 WarningA Warning identifies conditions and actions that pose ha-zards to the user. To avoid electrical shock or personal injury, follow t

Seite 24

30576MaintenanceLens Cleaning:Blow off loose particles using clean compressedair. Brush remaining de-bris away with a camel’s hair brush.Wipe the surf

Seite 25

31576This instrument conforms to the followingstandards:EMC: - EN 61326-1:1997+A1:1998+A2:2001Safety: - EN 61010-1:2001 - EN 60825-1:2001This produ

Seite 26 - Mode - Thermocouple Settings

32576SpecificationsTemp. Range - 30 to 900°C (- 25 to 1600°F)Display Resolution 0.1°C (0.2°F)Accuracy (Infrared)at 25°C (77°F) ambient temperature± 0.7

Seite 27 - DIP Switches

33576Specifications of the CameraMaximum Picture Number640x480 Pixels (VGA)26Maximum Picture Number320x240 Pixels (1/4 VGA)100Recharge Time for Flash a

Seite 28 - Troubleshooting

4576Table of ContentsIntroduction ... 5Symbols and Safety Markings ...

Seite 29

576The Fluke Model 576 Infrared Thermometer (the thermometer) is for non-contact temperature measurement. This thermometer determines an object‘s surf

Seite 30 - Maintenance

6576Symbol Explanation Risk of danger. Important information. See Manual. Risk of danger. Important information. See Manual. Risk

Seite 31 - CE Conformity

7576Laser Warning and Serial Number Labels

Seite 32 - Specifications

8576 • The unit • Getting Started • Two AA batteries • Manual on CD • Thermocouple type K probe • Windows-based software on CD • USB cab

Seite 33 - Specifications of the Camera

9576Batteries and MeasurementTo open the battery compartment, press gently on the top part ofthe handleto releasethe catch and pivot thegrip as shown