COMMAND REFERENCE 4 - 53
DISPlay:WINDow2:TEXT[1]:STATe
Syntax:
DISPlay:WINDow2:TEXT[1]:STATe <Boolean>
2 Indicates that the user text field is window 2.
Query form:
DISPlay:WINDow2:TEXT[1]:STATe?
Response:
0 | 1
0 Display turned off.
1 Display turned on.
Description:
Switches the display of the user text field on or off.
After a
*
RST command, the display of user text is turned off.
Example:
Send
DISPlay:WINDow2:TEXT:STATe OFF Turns off the display of the
user text.
Front panel compliance:
The DISPlay:WINDow2:TEXT:STATe command is the remote equivalent of the
"user text on/off" option of the front panel DISPLAY - TEXT menu.