DSP-100/2000
Users Manual
4-2
Scanning Function
The Single Test versions of the wire map, resistance, TDR, and TDX analyzer
tests include a scanning function, which you can activate by pressing the
#Scanning ON softkey. The scanning function runs the test repeatedly
and updates the display each time a test is complete. This function is useful for
finding intermittent problems on a cable.
Note
To extend battery life, connect the ac adapter/charger when using
the scanning function for more than 1 minute.
When to Use a Remote Unit
A remote unit is required only when testing twisted pair cable. Table 4-1 shows
which cable tests require a remote and which remotes support each test.
If a remote unit is detected at the start of a Single Test, the test tool runs a wire
map test before running the selected test. If the wire map test fails, the test tool
stops the test and displays the wire map. Press $Continue Test to run
the selected test.
Note
Model DSP-2000 is compatible only with Model DSP-2000SR units.
Model DSP-100 is not compatible with Model DSP-2000SR units.